Description
🏗️ Before you order — a cassette AC needs a false ceiling. Please check this first.
This is a ceiling-recessed unit, not a wall-mounted split. The indoor body is 256 mm deep and must sit inside a ceiling void, with the 950 × 950 mm decorative panel flush to the ceiling below it. That means you need an existing false ceiling with at least 256 mm of clear space above it, plus structural support for a 22 kg unit and access for drainage.
If your space doesn't have a false ceiling, one has to be built — a separate cost and a separate contractor. Send us a photo of your ceiling and we'll tell you honestly whether this will work before you commit. Call 9710000251.
360° Surround Airflow. 2 Ton Cassette.
Fresh Air Intake · 27.5 dB · ISEER 3.65 · Japanese Engineering.
23,987 BTU/h · 5800W max cooling · for 240–300 sq ft · 5-speed fan · 1,491 kWh/year · 20m max piping · 19–48°C operating range · IDU 22kg · ODU 46.5kg · 230V single phase
A wall-mounted split blows air in one direction — which is why the far corner of a wide room never quite cools and the people sitting nearest the unit are always too cold. A ceiling cassette sits in the middle of the ceiling and discharges from all four sides simultaneously, so cool air reaches every corner at roughly the same time and temperature. In an office, showroom, café or large hall, that's the difference between one comfortable zone and a genuinely comfortable room. It also frees your entire wall area — no indoor unit taking up prime wall space above a display, a counter or a whiteboard.
Fresh Air Intake — the feature that separates commercial cooling from domestic
Most air conditioners recirculate the same indoor air endlessly. In a sealed office or café with people in it all day, carbon dioxide builds up and air goes stale — it's a large part of why meeting rooms feel stuffy and afternoon concentration drops. This unit draws in a proportion of outdoor air and mixes it with the recirculated air, continuously refreshing the room. For any space where people spend full working days, that's a genuine occupant-comfort feature rather than a specification line.
🔇 Five fan speeds — noise from 37 dB down to 27.5 dB
27.5 decibels is below a whisper. For a cassette running above people's heads all day, the lowest setting matters more than the highest.
⚡ Energy & performance — fully disclosed, which is rare on commercial units
Honest note: 2 Star is a modest rating, but 1,491 kWh is stated precisely — so you can calculate the actual running cost against your commercial tariff rather than guessing from a star badge. Ask us to model it against an inverter cassette if the unit will run long daily hours.
📐 Unit dimensions & weights — plan your installation properly
Indoor Cassette Body
840 × 840 × 256 mm
22 kg
Sits inside the ceiling void
Decorative Panel
950 × 950 × 50 mm
5.5 kg
Visible flush at ceiling level
Outdoor Unit
845 × 300 × 595 mm
46.5 kg
Max 20 m piping · 10 m height difference
Gradually adjusts the set temperature through the night so the room doesn't become uncomfortably cold in the early hours. Useful in residential installations and in any space occupied overnight, such as a clinic or guest area.
Resumes previous settings automatically when power returns — essential in Delhi NCR, and particularly for a commercial space where nobody may be present to restart it after an outage. The timer allows scheduled operation around business hours.
Zero ozone depletion potential, substantially lower global warming potential than older R-410A, and better thermodynamic efficiency so the compressor does more cooling per unit of energy. It's also the refrigerant the industry is standardising on, keeping future servicing straightforward.
Rated to keep working up to 48°C ambient. Delhi NCR afternoons reach 45–47°C in May and June, so this sits inside the envelope — but with less headroom than some units. If the outdoor unit will sit on an exposed terrace in direct sun, tell us and we'll advise on shading and placement.
🎯 Ideal for
| Indoor Unit | Daikin FCQF24ARV16 (ceiling cassette) |
| Outdoor Unit | Daikin RGVF24ASV16 |
| Type | Non-Inverter Ceiling Cassette |
| Capacity | 2 Ton · 23,987 BTU/h ✅ |
| Cooling Capacity (Max) | 5800 W ✅ |
| Coverage | 240–300 sq. ft. |
| BEE Rating | 2 Star (2025 BEE) |
| ISEER | 3.65 ✅ |
| Annual Power Consumption | 1,491 kWh ✅ |
| Power Input | 1,926 W · 230V ~ 50Hz single phase ✅ |
| Compressor | Rotary (non-inverter) |
| Refrigerant | R-32 ✅ |
| Airflow Rate | 812 / 742 / 653 / 565 CFM ✅ |
| Noise (Indoor) | 37 / 34.5 / 32 / 29.5 / 27.5 dB ✅ |
| Airflow Pattern | 360° surround · Fresh Air Intake |
| Modes | Good Sleep · Auto Restart · Timer |
| Indoor Unit Size / Weight | 840 × 840 × 256 mm · 22 kg ✅ |
| Panel Size / Weight | 950 × 950 × 50 mm · 5.5 kg ✅ |
| Outdoor Unit Size / Weight | 845 × 300 × 595 mm · 46.5 kg ✅ |
| Max Piping / Height Difference | 20 m / 10 m ✅ |
| Operating Range | 19 °C – 48 °C |
| In the Box | Indoor cassette · outdoor unit · decorative panel kit · remote · installation accessories · manual · warranty card |
Why buy from Mahajan Electronics?
- We assess your ceiling before you commit
- 45+ years of retail trust & expertise
- 24-hour express delivery across Delhi NCR
- GST invoice — save up to 18% on business purchases
- Professional installation & after-sales team
- Raja Garden · Jail Road · Dabri Mod
Send us a photo of your ceiling. We'll advise before you order.
2 Ton Ceiling Cassette · 360° Airflow · Fresh Air Intake · ISEER 3.65 · 1,491 kWh · 27.5 dB · R32 · Daikin
Requires a false ceiling with 256mm+ void. Non-inverter. Compressor warranty not stated — confirmed in writing before order. Copper piping not itemised; get a full installation quote. Image for reference only.