Description
2 Ton. ISEER 4.40. 1,238 Units/Year. 54Β°C.
Swing Compressor Β· 5-Step Convertible Β· Coanda Airflow Β· PM2.5 Filter Β· Stabiliser Inside.
Large-room inverter split AC for 150β200 sq ft Β· 7.03 kW cooling Β· swing compressor Β· 16m air throw Β· 745 CFM Β· Dew Clean Β· Power Chill Β· triple display Β· 130β285V stabiliser-free Β· R32 Β· 1060Γ325Γ278 mm IDU Β· 845Γ595Γ300 mm ODU
ISEER 4.40 on a 3-star unit β what that actually means for your bill
1,238 units per year at standard test conditions. At Delhi NCR's average of βΉ8/unit, that's roughly βΉ9,900/year if you run it 8 hours daily through the cooling season. Here's the honest comparison: a 5-star 2-ton inverter (ISEER ~5.0β5.2) would consume ~950β1,050 units/year β saving βΉ1,500β2,300 annually. Over 5 years, that's βΉ7,500β11,500 in electricity savings. The 5-star premium is typically βΉ8,000β12,000 more upfront. So for heavy use (10+ hrs/day), the 5-star wins on total cost. For moderate use (4β6 hrs/day), this 3-star's lower purchase price makes it the smarter buy. The ISEER of 4.40 is actually quite good for a 3-star β many 3-star units score 3.8β4.0. Daikin has tuned this model closer to 4-star efficiency while keeping the 3-star price point.
π 5-Step Convertible Cooling β Adjust Capacity to Your Need
The swing compressor adjusts its speed to match the selected tonnage β not just a thermostat tweak, but actual capacity reduction. Use 100% for peak summer afternoons, 70% for monsoon humidity, and 40% for night sleeping or when only 1β2 people occupy the room. This is where the real savings come from: a fixed-speed 2-ton AC runs at full power even when you only need 0.8 tons. At 40% mode, this Daikin uses roughly 900W instead of 2,230W β cutting your hourly cost by 60%.
Daikin Swing Compressor β why it's different from standard rotary
Standard rotary compressors use a fixed vane that scrapes the cylinder wall, creating friction and noise. Daikin's swing compressor replaces the vane with a smooth, orbiting swing motion β no contact scraping, less friction, lower noise, and higher efficiency. The result: quieter operation (especially at low speeds), longer compressor life, and better part-load efficiency β which is where inverter ACs spend 80% of their running time. In Delhi NCR's dust and heat, the reduced mechanical wear translates to fewer service calls in years 5β8. It's a genuine engineering advantage, not a marketing name.
Standard ACs blow cold air directly at you, creating a "cold spot" under the airflow and warm corners elsewhere. Coanda airflow uses specially angled louvres to direct air along the ceiling, letting it cascade down the walls and fill the room evenly. You feel comfortable cooling without the direct blast of 16Β°C air on your face. Particularly valuable in large living rooms where people sit in different positions β no one gets the direct hit, everyone gets consistent temperature.
Removes particulate matter down to 2.5 microns β the size of Delhi NCR's most harmful pollution. The 3-stage system typically means: pre-filter (large dust/hair), electrostatic filter (fine particles), and activated carbon (odors/VOCs). Wash the pre-filter every 2 weeks during heavy use; the electrostatic layer needs professional cleaning annually. The filter is not a HEPA-grade medical filter β it reduces exposure, it doesn't eliminate it. For severe allergy sufferers, consider adding a standalone air purifier.
Auto-cleans the indoor evaporator coils using condensation water. The AC runs a brief heating cycle that warms the wet coils, loosening dust and microbial film, which then drains away. Extends the interval between professional deep cleans from 3β4 months to 6β8 months. Does NOT clean the outdoor unit, air filter, or drain pipe β those still need manual attention. Think of it as daily dental hygiene; professional service is still the dentist visit.
Power Chill overrides settings and runs maximum cooling for 10β15 minutes to pull down a hot room fast, then returns to your set temperature. The triple display shows: (1) real-time power consumption as a percentage, (2) room temperature vs set temperature, and (3) error codes for self-diagnosis. The power consumption display is genuinely useful β you can see exactly how much the 5-step convertible modes save you in real time.
Built-in voltage protection eliminates the need for an external stabiliser β saving βΉ2,000β3,500 and one more device that can fail. Covers the full range of Delhi NCR voltage fluctuations, including low-voltage brownouts (130V) and high-voltage spikes (285V). If your area sees drops below 130V or spikes above 285V, call us and we'll assess whether additional protection is needed. Most Delhi NCR neighbourhoods stay within this range.
Indoor: 1060 Γ 325 Γ 278 mm (1.06m wide β confirm your wall space). Outdoor: 845 Γ 595 Γ 300 mm. Both units are substantial; the IDU needs a solid brick or concrete wall (not hollow partition). The ODU at 845mm wide needs a platform or bracket that can support 40β50 kg. We provide professional installation including wall assessment, bracket supply, and levelling. Call us for a site visit before delivery.
| Brand / Model | Daikin FTKL71XV16 (2026 Model) |
| Type | Inverter Split Air Conditioner |
| Capacity | 2.0 Ton β |
| Cooling Capacity | 7.03 kW β |
| BEE Rating | 3 Star (2026) β |
| ISEER | 4.40 β |
| Annual Power Consumption | 1,238 Units β |
| Compressor | Daikin Swing Compressor β |
| Refrigerant | R32 (Eco-Friendly) β |
| High Ambient | Cools up to 54Β°C β |
| Air Throw | Up to 16 metres β |
| Air Flow | 745 CFM β |
| Voltage Range | 130β285V (Stabiliser Inside) β |
| Convertible Cooling | 5-Step (100%/85%/70%/55%/40%) β |
| Airflow Technology | Coanda Airflow β |
| Filtration | PM2.5 Filter + 3-Stage Filtration β |
| Self-Cleaning | Dew Clean Technology β |
| Fast Cooling | Power Chill Operation β |
| Display | Triple Display (Power %, Temp, Error Codes) β |
| Indoor Unit Dimensions | 1060 Γ 325 Γ 278 mm β |
| Outdoor Unit Dimensions | 845 Γ 595 Γ 300 mm β |
| Remote | Backlit Wireless Remote β |
| In the Box | Indoor unit Β· outdoor unit Β· interconnecting copper pipe Β· backlit remote Β· user manual Β· warranty card |
| Warranty (Standard) | 1yr comprehensive + 5yr PCB + 10yr compressor |
| Warranty (Promo: 2β31 July 2026) | 5yr comprehensive (compressor, PCB, motors, coils, sensors) β |
Why buy from Mahajan Electronics?
- Transparent installation quoting β copper pipe length assessed upfront
- 45+ years of trusted retail excellence
- 24-hour delivery across Delhi NCR
- GST invoice β save up to 18% on business purchases
- 100% genuine Daikin products Β· authorised dealer
- Raja Garden Β· Jail Road Β· Dabri Mod
Order today. Delivered in 24 hours.
Daikin FTKL71XV16 Β· 2 Ton Β· 3 Star Inverter Split AC Β· ISEER 4.40 Β· 1,238 Units/Year Β· Swing Compressor Β· 5-Step Convertible Β· Coanda Airflow Β· PM2.5 Filter Β· Dew Clean Β· Stabiliser Inside 130β285V Β· 54Β°C Β· R32 Β· 2026 Model
Please Note: The image shown is for reference purposes only. Actual product details, including the serial number and manufacturing date, may vary.
Β




